341

Highly sensitive ELISAs in 90-minutes: SimpleStep ELISA kits and the SPECTROstar Nano

(1) Abcam, Cambridge, UK, (2) BMG LABTECH, Cary, NC 10/2019 Mallori Milligan (1), Scott Detmer (1), Carl Peters (2) (1) Abcam, Cambridge, UK, (2) BMG LABTECH, Cary, NC 10/2019
  • Single-wash protocol reduces assay time but maintains high sensitivity, speci fi city and reproducibility
  • Using the SPECTROstar Nano and MARS data reduction software, simpli fi es assay detection and analysis

Table of contents

Introduction

Since its introduction in the early 1970's the enzyme-linked immunosorbent assay (ELISA) has become one of the most reliable and relied upon biochemical assays 1. Detecting the presence (and quantity) of an analyte has proved an invaluable tool as a diagnostic in medicine or in basic research spanning nearly every biological discipline.


The main drawbacks of the ELISA approach have always been the relatively low throughput and the tedium of multiple wash steps that normally take 3-5 h to perform. Abcam's SimpleStep ELISA ® technology addresses these issues by streamlining the process to a semi-homogeneous format that results in a simple 90-minute, single wash protocol.


Here, we describe the detection of this innovative ELISA by the SPECTROstar Nano . When combined with MARS data analysis you will get your great results in the fastest, easiest way possible.


Examplary data are shown for three important targets:

  • Human Pro-Collagen I alpha: The protein is a component of type I collagen that is found in bones and cartilage. Hence, it is implicated in diseases characterized by fragile bones such as osteogenesis imperfecta or osteoporosis.
  • Human IL6: Interleukin 6 (IL6) is an in fl ammatory cytokine that is capable of inducing maturation of B-cells and fever. Therefore, it is often used as an in fl ammation marker.
  • GFP: Green fl uorescent protein (GFP) is characterized by its ability to fl uoresce in the green spectrum when excited by blue light. It is a popular protein, when coupled to a protein of interest.

Assay Principle

The sandwich ELISA uses an antibody pair that binds distinct parts of the analyte. One antibody coats the bottom of the well and serves to capture the analyte. Following capture, and requisite washing, the detector antibody is added. Finally, after additional washing, the detection can be performed.


Figure 1 shows how SimpleStep ELISA ® technology enables the sandwich ELISA to be performed semi-homogeneously by the addition of an immobilization antibody.

Materials & Methods

  • SPECTROstar Nano
  • SimpleStep ELISA ® kits
    • Human Pro-Collagen I alpha 1 ELISA kit (ab210966)
    • Human IL-6 ELISA kit (ab178013)
    • GFP ELISA kit (ab171581)

Experimental Procedure
For all kits, samples were handled in accordance with instructions 2. For all tests, standard curves were prepared based on an 8-point dilution series using duplicate samples. Pro-Collagen 1 alpha and IL-6 used a 2-fold dilution series with starting concentrations of 2000 and 500 pg / mL respectively. GFP used a 3-fold dilution series with a starting concentration of 2000 pg / mL. Assay reproducibility was determined using biological replicates, which included 2 different dilutions of human serum for Pro-Collagen I alpha, 2 dilutions of stimulated peripheral mononuclear blood cells (PMBC) supernatant for IL-6, and 143B cells spiked with 500 and 250 pg / mL of GFP.


Plates were read on a SPECTROstar Nano with the following settings:

Instrument settings

Optic settings Absorbance spectrum, Endpoint test
Wavelength range (step width) 400-700 (2) nm
General settings Number of flashes 45
Settling time 0.2 s

Results & Discussion

BMG LABTECH microplate readers are equipped with a spectrometer for absorbance detection. Collection of spectral data can be done in the same time as reading a single wavelength. This allows easy evaluation of data quality (Figure 2). MARS data analysis templates allow automatic wavelength selection including peak, off-peak and reference wavelengths, for additional calculations that are also performed automatically by the system.

Figure 3 demonstrates how data from the SimpleStep ELISA ® kit conforms to the suggested 4-parameter fi t. An R2 of at least 0.9995 was seen for all three kits used.

Table 1 shows the results of sensitivity and reproducibility metrics calculated for all 3 kits. These results indicate that SimpleStep ELISA ® kits do not sacri fi ce performance while improving ease-of-use taking only one-third of the time to complete than a typical ELISA.


Table 1: SimpleStep ELISA ® Sensitivity and Assay Precision
MDD (minimum detectable dose) = recalculated concentration of AvgBlank + 2 * SD Blank . Blank (n = 15), bio-replicates (n = 8).

MDD (pg / mL) % CV of Blanks % CV of bio-replicates Dil. 1 % CV of bio-replicates Dil. 2
Pro-collagen <8.1 4.7 1.3 3.3
GFP 1.16 4.4 3.8 7.6
IL-6 <1.99 8.4 3.8 3.4

Conclusion

SimpleStep ELISA ® kits offer excellent sensitivity and performance while saving signi fi cant time and effort. Reading microplates with the SPECTROstar Nano provides notable data quality while offering the convenience of linking data analysis to MARS templates, for immediate and accurate results.

ELISA Working Principle

6 Tips for Optimizing your ELISA Assays

This Article gives tips to improve the quality and throughput of your ELISA Assays with a Microplate Reader.

Read more

References

1. Lequin, RM Enzyme Immunoassay (EIA) / Enzyme-Linked Immunosorbent Assay (ELISA). Clin. Chem. (2005) 51: 2415-2418.
2. SimpleStep ELISA ® kits: www.abcam.com/kits/simplestep-elisa-kits

Compatible readers

  • BMG LABTECH microplate reader PHERAstar FSX from the front view

    PHERAstar FSX

  • BMG LABTECH microplate reader SPECTROstar Nano from the front view

    SPECTROstar Nano

  • Frontview of the FLUOstar Omega, a microplate reader from the BMG LABTECH Omega series

    Omega series

  • BMG LABTECH microplate reader CLARIOstar Plus from the front view

    CLARIOstar Plus

go to top